![]() ![]() Longer weirs allow more water to flow out of the sedimentation basin without exceeding the recommended water velocity. The standard weir overflow rate is 10,000 to 14,000 gpd/ft and should be less than 20,000 gpd/ft. Weir loading, also known as weir overflow rate, is the number of gallons of water passing over a foot of weir per day. Overflow rate should usually be less than 1,000 gal/day-ft.2 The weir loading is another important factor in sedimentation basin efficiency. The present practice for the design of primary settling tanks is based on the overflow rate corresponding to the percentage removal using isoremoval plots. ![]() Surface loading is calculated by dividing the flow by the surface area of the tank. The overflow rate (also known as the surface loading or the surface overflow rate) is equal to the settling velocity of the smallest particle which the basin will remove. Instead, two additional characteristics are important in designing a sedimentation basin. Designing a Rectangular Sedimentation Tank Introduction Designing a rectangular sedimentation tank is similar in many ways to designing a flocculation chamber. However, water in a sedimentation basin is not agitated, so the velocity gradient is not a factor in the calculations. Lesson 13: Sedimentation Basin Design and ProblemsÄesigning a Rectangular Sedimentation Tank Introduction Designing a rectangular sedimentation tank is similar in many ways to designing a flocculation chamber. ![]()